Uses For a variety of ships and offshore oil platform building water
power, lighting and electrical installations. Executive Standard This product is the implementation of GB9331 standards, equivalent
to using IEC92-356 standard. Use characteristics 1, Rated voltage: 0.6/1KV. 2, Yun-meter long cable conductor temperature: PVC insulated cable 70 ℃; Cross-linked polyethylene insulated cable 90 ℃; Ethylene-propylene rubber insulated cables 70 ℃; 3, cable laying low temperature: PVC sheathed cable -15 ℃, other cable -20 ℃. 4, the cable morning small bend radius: Metal braided armor-type not less than 6 times the cable diameter; Non-sheathed-type not less than 4 times the cable diameter. 5, fire-retardant features: A single vertical flame retardant cable able to withstand the
GB/T18380.2 (IEC60332-2) provided for a single vertical burning test; Into the beam flame retardant cable able to withstand the
GB/T18380.3 (IEC60332-3) Into a beam under the fire test; Low smoke zero halogen flame retardant cable into the beam can
withstand GB/T18380.3 (IEC60332-3) into a beam under the fire test.